Repository logo
 

Wind-tunnel study of chimney downwash at the B.L. England Station of the Atlantic City Electric Company: report

dc.contributor.authorCermak, Jack E., author
dc.contributor.authorPeterka, Jon A., author
dc.contributor.authorBeatty, J. A., author
dc.contributor.authorFluid Mechanics and Wind Engineering Program, Fluid Dynamics and Diffusion Laboratory, Department of Civil Engineering, Colorado State University, publisher
dc.coverage.spatialAtlantic City (N.J.)
dc.date.accessioned2016-01-29T19:47:57Z
dc.date.available2016-01-29T19:47:57Z
dc.date.issued1984-06
dc.descriptionCER83-84JEC-JAP30.
dc.descriptionCER83-84JEC-JAP-JAB30a.
dc.descriptionCER83-84JEC-JAP30b.
dc.descriptionIncludes bibliographical references.
dc.descriptionJune 1984.
dc.descriptionCSU Project 2-95800.
dc.descriptionPrepared for Stearns-Roger Engineering Corporation.
dc.description.abstractThe Atlantic City Electric Company has measured SO2 concentrations, downwind from one of their electrical power generating stations, which occasionally exceed regulatory limitations. The problem (suspected to be plume downwash induced by adjacent buildings) was referred to the Stearns-Roger Engineering Corporation for further study. The study included wind-tunnel simulation, which was subcontracted to Colorado State University. Diffusion tests were subsequently conducted on a 1:300 scale model of the B. L. England Station (a coal and oil fired electrical power generation facility) in the CSU Meteorological Wind Tunnel. Their purpose was to confirm the downwash and to determine the effect of various changes in stack/site configuration upon plume behavior. The model tests, conducted at pre-selected wind directions and velocities, included physical alterations in the station site, increases in momentum and buoyancy of the flue gases, increases in height of the existing stacks, and inspection of two new stacks - GEP and greater. Data obtained included ground-level concentration measurements for all tests and visualization of selected configurations. The model tracer gas concentrations were converted to equivalent prototype SO2 concentrations for comparison with any similar field data. The visualization studies were documented on 35 mm slides, B&W photos, and video cassette. Evaluation of test results indicates that significant downwash is caused by the boiler buildings. The data further reveal that those configurations which increased the plume height above the building influence are practicable measures to mitigate the downwash phenomenon. Extension of the existing stacks when accompanied by flue gas reheat provide SO2 reductions nearly equal to a GEP stack.
dc.format.mediumreports
dc.identifier.urihttp://hdl.handle.net/10217/170590
dc.languageEnglish
dc.language.isoeng
dc.publisherColorado State University. Libraries
dc.relationCatalog record number (MMS ID): 991012060639703361
dc.relationTA7.C6 CER 83/84-30
dc.relation.ispartofCivil Engineering Reports
dc.relation.ispartofCER, 83/84-30, 30a, 30b
dc.rightsCopyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.
dc.subjectAtlantic City (N.J.) -- Buildings, structures, etc.
dc.subject.lcshWind tunnel models
dc.subject.lcshBuildings -- New Jersey -- Atlantic City -- Aerodynamics
dc.subject.lcshChimneys
dc.titleWind-tunnel study of chimney downwash at the B.L. England Station of the Atlantic City Electric Company: report
dc.typeText
dcterms.rights.dplaThis Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).

Files

Original bundle
Now showing 1 - 3 of 3
Loading...
Thumbnail Image
Name:
CERF_Peterka_Cermak_Beatty.pdf
Size:
9.92 MB
Format:
Adobe Portable Document Format
Description:
Report
Loading...
Thumbnail Image
Name:
CERF_Peterka_Cermak_Beatty_2.pdf
Size:
9.02 MB
Format:
Adobe Portable Document Format
Description:
Appendix A
Loading...
Thumbnail Image
Name:
CERF_Peterka_Cermak_Beatty_3.pdf
Size:
2.49 MB
Format:
Adobe Portable Document Format
Description:
Appendix B