Dynamic response of pressure transmission lines to pulse input: technical report

dc.contributor.authorGorove, Arpad, author
dc.contributor.authorCermak, J. E. (Jack E.), author
dc.contributor.authorFluid Dynamics and Diffusion Laboratory, College of Engineering, Colorado State University, publisher
dc.date.accessioned2019-09-17T19:15:31Z
dc.date.available2019-09-17T19:15:31Z
dc.date.issued1967-06
dc.descriptionCER66-67AP-JEC51.
dc.descriptionJune 1967.
dc.descriptionU.S. Army Research Grant.
dc.descriptionIncludes bibliographical references.
dc.description.abstractThe dynamic response of pressure transmission lines to pulse input was investigated experimentally. The most commonly used commercially available flexible Tygon tubings were examined at a constant 1/ 2-psi air pressure with a frequency up to 300 cps. Short tubings, from 1 inch to 3 feet and inside diameters between .052 inch and 1/4 inch, were tested in the experiment. Pressure transducers were selected which had very small internal volume and the reference transducer was kept at a practical minimum distance from the pressure source. Tubing with and without inlet restriction has been investigated to determine the phenomenon of resonant frequency. To determine the effect of the elastic wall of the tubing on the pressure response, comparison measurements were taken in rigid wall, flexible Tygon, and rubber tubings. Phase shift of flexible tubings with various lengths and inside diameters were determined for the frequency range 0-300 cps.
dc.description.sponsorshipUnder grant DA-AMC-28-043-65-G20.
dc.format.mediumtechnical reports
dc.identifier.urihttps://hdl.handle.net/10217/198074
dc.languageEnglish
dc.language.isoeng
dc.publisherColorado State University. Libraries
dc.relationCatalog record number (MMS ID): 991012732069703361
dc.relation.ispartofCivil Engineering Reports
dc.relation.ispartofCER, 66/67-51
dc.rightsCopyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.
dc.subjectPressure -- Measurement
dc.titleDynamic response of pressure transmission lines to pulse input: technical report
dc.typeText
dcterms.rights.dplaThis Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
CERF_66-67_51.pdf
Size:
17.15 MB
Format:
Adobe Portable Document Format
Description: