Atmospheric transport of hydrogen sulfide from proposed geothermal power plant (units 13, 14, 16, and 18) for the west wind direction: predictions by physical modeling in a wind tunnel
dc.contributor.author | Cermak, Jack E., author | |
dc.contributor.author | Petersen, Ronald L., author | |
dc.contributor.author | Fluid Dynamics and Diffusion Laboratory, Fluid Mechanics and Wind Engineering Program, Colorado State University, publisher | |
dc.date.accessioned | 2017-05-01T20:19:19Z | |
dc.date.available | 2017-05-01T20:19:19Z | |
dc.date.issued | 1977-11 | |
dc.description | CER77-78RLP-JEC10. | |
dc.description | Prepared for Pacific Gas and Electric Company. | |
dc.description | Includes bibliographical references (page 12). | |
dc.description | November 1977. | |
dc.description.abstract | Tests were conducted in the Colorado State University environmental wind tunnel facility of the transport and dispersion of the H2S plume emanating from cooling towers positioned at four locations in the Geysers area. The wind tunnel tests were conducted with the cooling towers and terrain modeled to a scale of 1:1920. Ground-level concentrations were measured in the vicinity of Anderson Springs for selected wind speeds and one wind direction. Ground-level concentration patterns were established for each test condition studied. Data obtained include photographs and motion pictures of smoke plume trajectories as well as ground-level tracer gas concentrations downwind of the cooling towers. | |
dc.format.medium | reports | |
dc.identifier.uri | http://hdl.handle.net/10217/180243 | |
dc.language | English | |
dc.language.iso | eng | |
dc.publisher | Colorado State University. Libraries | |
dc.relation | Catalog record number (MMS ID): 991012549679703361 | |
dc.relation | TA7.C6 CER 77/78-10 | |
dc.relation.ispartof | Civil Engineering Reports | |
dc.relation.ispartof | CER, 77/78-10 | |
dc.rights | Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright. | |
dc.subject | Geothermal power plants -- Environmental aspects -- California -- Lake County | |
dc.subject | Wind tunnel models | |
dc.subject | Hydrogen sulfide | |
dc.subject | Atmospheric diffusion | |
dc.subject | Mathematical models | |
dc.title | Atmospheric transport of hydrogen sulfide from proposed geothermal power plant (units 13, 14, 16, and 18) for the west wind direction: predictions by physical modeling in a wind tunnel | |
dc.type | Text | |
dcterms.rights.dpla | This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s). |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- CERF_Petersen_Cermak_5.pdf
- Size:
- 30.32 MB
- Format:
- Adobe Portable Document Format
- Description: