Repository logo
 

Electrical impedance tomography with Calderón's method in two and three dimensions

dc.contributor.authorShin, Kwancheol, author
dc.contributor.authorMueller, Jennifer L., advisor
dc.contributor.authorCheney, Margaret, committee member
dc.contributor.authorPinaud, Olivier, committee member
dc.contributor.authorHussam, Mahmoud, committee member
dc.date.accessioned2020-08-31T10:12:03Z
dc.date.available2021-08-24T10:12:03Z
dc.date.issued2020
dc.description.abstractElectrical impedance tomography (EIT) is a non-invasive imaging technique in which electrical measurements on the electrodes attached to the boundary of a subject are used to reconstruct the electrical properties of the subject. That is, voltage data arising from currents applied on the boundary are used to reconstruct the conductivity distribution in the interior. Calderón's method is a direct linearized reconstruction method for the inverse conductivity problem with the attributes that it can provide absolute images with no need for forward modeling, reconstructions can be computed in real-time, and both conductivity and permittivity can be reconstructed. In this three-paper dissertation, first, an explicit relationship between Calderón's method and the D-bar method is provided, facilitating a "higher-order" Calderón's method in which a correction term is included, derived from the relationship to the D-bar method. Furthermore, a method of including a spatial prior is provided. These advances are demonstrated on tank data collected with the ACE1 EIT system. On the other hand, it has been demonstrated that various EIT reconstruction algorithms are very sensitive to the measurement and incorrect modeling of the boundary shape. Calderón's method has been implemented with correct boundary shape, but the exact location of the electrodes are disregarded as they are assumed to be spaced uniformly in angle. In the second body of work, Calderón's method is implemented with a new expansion technique which enables the use of the correct location of the electrodes as well as the shape of the boundary resulting in improved absolute images. We test our new algorithm with experimental data collected with the ACE1 EIT system. Finally, the first implementation of Calderón's method on a 3-D cylindrical domain with data collected on a portion of the boundary is provided. The effectiveness of the method to localize inhomogeneities in the plane of the electrodes and in the z-direction is demonstrated on simulated and experimental data.
dc.format.mediumborn digital
dc.format.mediumdoctoral dissertations
dc.identifierShin_colostate_0053A_16191.pdf
dc.identifier.urihttps://hdl.handle.net/10217/211806
dc.languageEnglish
dc.language.isoeng
dc.publisherColorado State University. Libraries
dc.relation.ispartof2020-
dc.rightsCopyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.
dc.subjectelectrical impedance tomography
dc.subjectmedical imaging
dc.subjectCalderón's method
dc.subjectPDEs
dc.subjectinverse problems
dc.titleElectrical impedance tomography with Calderón's method in two and three dimensions
dc.typeText
dcterms.embargo.expires2021-08-24
dcterms.embargo.terms2021-08-24
dcterms.rights.dplaThis Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
thesis.degree.disciplineMathematics
thesis.degree.grantorColorado State University
thesis.degree.levelDoctoral
thesis.degree.nameDoctor of Philosophy (Ph.D.)

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Shin_colostate_0053A_16191.pdf
Size:
7.34 MB
Format:
Adobe Portable Document Format