dc.description.abstractThe objective of this research is to provide accurate reliable data for use in an irradiation facility and present findings in a manner useful to operators. The intended use of the irradiator and irradiator protocols dictate a need for a well-known administered dose. Dose rates from two independent methods were investigated at multiple distances away from the source. First, the irradiation platforms were examined for "hot spots" using Gafchromic © film to provide a qualitative estimate of the dose distribution. A quantitative assessment of doses was then performed using Fricke dosimetry (a primary standard). Finally, MCNP modeling was used to simulate irradiation at the various measured points and intermediate points in the radiation field. The results were used to provide dose rates within the radiation field for future researchers, and demonstrated how precision and accuracy vary using theoretical (MCNP) and measurement methodology. MCNP simulation matched the Fricke measurements within 10% for the first two positions explored, then diverged upon further movement from the source.
dc.format.mediumborn digital
dc.format.mediummasters theses
dc.identifierMarcinko_colostate_0053N_14080.pdf
dc.identifier.urihttp://hdl.handle.net/10217/181356
dc.languageEnglish
dc.language.isoeng
dc.publisherColorado State University. Libraries
dc.relation.ispartof2000-2019
dc.rightsCopyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.
dc.titleCalibration of an irradiation facility
dc.typeText
dcterms.rights.dplaThis Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
thesis.degree.disciplineEnvironmental and Radiological Health Sciences
thesis.degree.grantorColorado State University
thesis.degree.levelMasters
thesis.degree.nameMaster of Science (M.S.)

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Marcinko_colostate_0053N_14080.pdf
Size:
682.11 KB
Format:
Adobe Portable Document Format