Wind-tunnel model of Shoreham Nuclear Power Station, Unit I, Long Island Lighting Company, part II: progress report

Date

1969-05

Authors

Meroney, Robert N., author
Cermak, Jack E., author
Chaudhry, Fazal Hussain, author
Fluid Dynamics and Diffusion Laboratory, College of Engineering, Colorado State University, publisher

Journal Title

Journal ISSN

Volume Title

Abstract

Tests were conducted in a meteorological wind tunnel to determine the distribution of gas concentrations resulting from gaseous plumes released from isolated stacks and short stacks varying in height on top of a model of the Shoreham Nuclear Power Station reactor building. The tests were conducted over a reactor complex model which included downstream topography for a critical flow direction of 345 degrees from called north. Data obtained included photographs of model smoke plume trajectories, plume ground impingement distances shown by indicator paints, and local concentration of Kr-85 at the reactor station site boundary. The effects of an additional reactor building expansion were also measured.

Description

CER68-69RNM-JEC-FHC14.
Shoreham Nuclear Powerplant (N.Y.).
Under contract to Stone and Webster Engineering Corporation, Boston (Mass.).
Includes bibliographical references (page 17).
May 1969.

Rights Access

Subject

Wind tunnel models
Buildings -- Aerodynamics

Citation

Associated Publications