Repository logo
 

Wind effects on tall buildings

dc.contributor.authorCermak, J. E. (Jack E.), author
dc.contributor.authorFluid Mechanics Program, Department of Civil Engineering, Colorado State University, publisher
dc.date.accessioned2017-11-27T15:16:29Z
dc.date.available2017-11-27T15:16:29Z
dc.date.issued1974
dc.descriptionCER73-74JEC-6.
dc.descriptionCEP73-74JEC-6.
dc.descriptionIncludes bibliographical references.
dc.description.abstractWind interacts with earth-bound buildings to produce both static and dynamic effects on the building. These include stressing of the primary frame through over all action of wind pressures, local loading of cladding panels and glass lights, and oscillation of tall buildings at their natural frequency through the phenomena of vortex shedding and galloping. On the other hand, buildings can modify the wind and cause an unpleasant or dangerous environment for pedestrians. All of the foregoing effects increase in intensity as building heights increase and are increased by the distributions of turbulence and mean wind, geometry of the building and surrounding structures, upwind surface roughness and topography and local climatological factors. The development of special meteorological wind tunnels during the last ten years has made simulation of natural winds associated with pressure gradients on a synoptic scale possible. This capability has enabled wind effects on tall buildings to be obtained by direct measurement on small-scale physical models and provides a reliable source of data for the design of even taller buildings of the future. However, neither a method to obtain design data nor adequate design methods have been developed which will give assurance that a tall building will not be damaged seriously by intense small-scale atmospheric disturbances such as a tornado.
dc.format.mediumreports
dc.identifier.urihttps://hdl.handle.net/10217/185076
dc.languageEnglish
dc.language.isoeng
dc.publisherColorado State University. Libraries
dc.relationCatalog record number (MMS ID): 991012240189703361
dc.relationTA7.C6 CER 73/74-6
dc.relation.ispartofCivil Engineering Reports
dc.relation.ispartofCER, 73/74-6
dc.rightsCopyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.
dc.subject.lcshBuildings -- Aerodynamics
dc.subject.lcshWind tunnel models
dc.titleWind effects on tall buildings
dc.typeText
dcterms.rights.dplaThis Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
CERF_73-74_06.pdf
Size:
7.62 MB
Format:
Adobe Portable Document Format
Description: