Wind tunnel model study of diffusion from a steam electric generating plant at Stock Island, Key West, Florida
dc.contributor.author | Meroney, R. N., author | |
dc.contributor.author | Cermak, Jack E., author | |
dc.contributor.author | Yang, B. T., author | |
dc.contributor.author | Veenhuizen, S., author | |
dc.contributor.author | Symes, C. R., author | |
dc.contributor.author | Fluid Dynamics and Diffusion Laboratory, College of Engineering, Colorado State University, publisher | |
dc.coverage.spatial | Key West (Fla.) | |
dc.date.accessioned | 2016-02-16T17:00:07Z | |
dc.date.available | 2016-02-16T17:00:07Z | |
dc.date.issued | 1969-08 | |
dc.description | Prepared under contract to R. W. Beck and Associates. | |
dc.description | CER69-70RNM-JEC-BTY-SV-CRS14. | |
dc.description | August 1969, Revised December 1969. | |
dc.description | Includes bibliographical references (pages 29-32). | |
dc.description.abstract | Tests were conducted in a meteorological wind tunnel to determine the distribution of gas concentrations resulting from gaseous plumes released from stacks associated with the steam electric generating plant to be constructed at Key West, Florida, on Stock Island. The tests were conducted over a model of the generating station including all proposed future expansions. Data obtained included photographs of model smoke plume trajectories and contaminant concentrations along the plume centerline at elevated and ground level sampling positions. Effects of wind orientation and thermal stratification were also analyzed. Evaluation of test results revealed the plant buildings did not appear to aggravate the pollution condition. However, a simple analysis suggests that SO2 scrubbing equipment may seriously aggravate the already marginal situation. | |
dc.format.medium | reports | |
dc.identifier.uri | http://hdl.handle.net/10217/170643 | |
dc.language | English | |
dc.language.iso | eng | |
dc.publisher | Colorado State University. Libraries | |
dc.relation | Catalog record number (MMS ID): 991012766899703361 | |
dc.relation | TA7.C6 CER 69/70-14 | |
dc.relation.ispartof | Civil Engineering Reports | |
dc.relation.ispartof | CER, 69/70-14 | |
dc.rights | Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright. | |
dc.subject | Wind tunnel models | |
dc.subject | Buildings -- Aerodynamics | |
dc.title | Wind tunnel model study of diffusion from a steam electric generating plant at Stock Island, Key West, Florida | |
dc.type | Text | |
dcterms.rights.dpla | This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s). |
Files
Original bundle