Repository logo
 

Wind-tunnel model of study of downwash from stacks at Maui Electric Company Power Plant, Kahului, Hawaii

dc.contributor.authorCermak, Jack E., author
dc.contributor.authorNayak, Shrinivas K., author
dc.contributor.authorFluid Dynamics and Diffusion Laboratory, Department of Civil Engineering, Colorado State University, publisher
dc.date.accessioned2017-05-26T19:51:11Z
dc.date.available2017-05-26T19:51:11Z
dc.date.issued1973-03
dc.descriptionCER72-73JEC-SKN28.
dc.descriptionPrepared under contract to Stearns-Roger Incorporated.
dc.descriptionIncludes bibliographical (pages 16-17).
dc.descriptionMarch 1973.
dc.description.abstractTests were conducted in the meteorological wind-tunnel using 1:200 scale model to determine the distribution of gas concentration resulting from gaseous plumes released from four stacks associated with Maui Electric Company Power-Plant at Kahului Hawaii. The tests were conducted over a model power-plant including all significant structures in the vicinity. Data obtained included photographs and color motion pictures of smoke-plume trajectories and plots of contaminant concentration down wind of the power-plant at ground-level sampling positions. The effects of wind direction and stack height on ground-level concentrations are established. Evaluation of test results revealed that an increase of stack height from 30.48 m to 60.96 m will reduce the maximum groundlevel concentrations by a factor of three to five depending upon the wind direction. Location of stacks upwind of the power-plant structures was found to show distinct improvement of plume characteristics.
dc.format.mediumreports
dc.identifier.urihttp://hdl.handle.net/10217/180905
dc.languageEnglish
dc.language.isoeng
dc.publisherColorado State University. Libraries
dc.relationCatalog record number (MMS ID): 991020973239703361
dc.relationTA7.C6 CER 72/73-28
dc.relation.ispartofCivil Engineering Reports
dc.relation.ispartofCER, 72/73-28
dc.rightsCopyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.
dc.subjectWind tunnels
dc.subjectBuildings -- Aerodynamics -- Testing
dc.titleWind-tunnel model of study of downwash from stacks at Maui Electric Company Power Plant, Kahului, Hawaii
dc.typeText
dcterms.rights.dplaThis Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).