Wind loads on a house roof

dc.contributor.authorDreher, K. J., author
dc.contributor.authorCermak, J. E. (Jack E.), author
dc.contributor.authorFluid Dynamics and Diffusion Laboratory, College of Engineering, Colorado State University, publisher
dc.date.accessioned2020-04-17T16:47:40Z
dc.date.available2020-04-17T16:47:40Z
dc.date.issued1973-03
dc.descriptionCER72-73KJD-JEC22.
dc.descriptionMarch 1973.
dc.descriptionIncludes bibliographical references (pages 40-42).
dc.descriptionPrepared under National Bureau of Standards Contract No. NBS 273-70.
dc.descriptionCirculating copy deaccessioned 2020.
dc.description.abstractThe wind loads on the roof of a house were experimentally investigated by placing a 1:50 scale model house in a wind tunnel capable of generating thick, turbulent shear flows. The effects of roof geometry and wind direction were isolated by making the wind-tunnel flow representative of natural winds over very flat, open terrain. This flow simulation was accomplished by placing vortex generators at the entrance to the wind-tunnel test section. Mean pressures, root-mean-square values of the fluctuating pressures, and instantaneous peak pressures were measured at 11 preselected locations on the model's roof for 24 wind directions. A secondary purpose of the study was to determine the effects of an upwind fence on the roof pressures.
dc.format.mediumtechnical reports
dc.identifier.urihttps://hdl.handle.net/10217/204897
dc.languageEnglish
dc.language.isoeng
dc.publisherColorado State University. Libraries
dc.relationCatalog record number (MMS ID): 991012239639703361
dc.relationTA .C7 CER 72/73-22
dc.relation.ispartofCivil Engineering Reports
dc.relation.ispartofCER, 72/73-22
dc.rightsCopyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.
dc.subject.lcshBuildings -- Aerodynamics
dc.subject.lcshRoofs -- Aerodynamics
dc.subject.lcshWind-pressure -- Measurement
dc.titleWind loads on a house roof
dc.typeText
dcterms.rights.dplaThis Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).