Evaluation of the performance of the floating rotor design flowmeter manufactured by the Pottermeter Company: flowmeter model 2-353A
dc.contributor.author | Karaki, Susumu, author | |
dc.contributor.author | Videon, Fred, author | |
dc.contributor.author | Colorado State University Research Foundation, publisher | |
dc.date.accessioned | 2017-12-11T16:07:26Z | |
dc.date.available | 2017-12-11T16:07:26Z | |
dc.date.issued | 1959-09 | |
dc.description | CER59SSK45. | |
dc.description | September 1959. | |
dc.description | Conducted for the Martin Company, Denver Division, Denver, Colorado through Colorado State University Research Foundation, Civil Engineering Section, Fort Collins, Colorado. | |
dc.description.abstract | This report presents an evaluation of the performance of a Pottermeter Model 2-353A. The original meter tested was found to give erratic results due largely to the formation of a vapor pocket at the stationary cone. The meter was redesigned by the Pottermeter Company and the results of tests of the revised meter showed improvement in performance characteristics. Tests for head loss and pressure distribution through the meter were also made and are reported herein. | |
dc.description.sponsorship | Under Martin Contract no. F8-51390. | |
dc.format.medium | reports | |
dc.identifier.uri | https://hdl.handle.net/10217/185438 | |
dc.language | English | |
dc.language.iso | eng | |
dc.publisher | Colorado State University. Libraries | |
dc.relation | Catalog record number (MMS ID): 991012085649703361 | |
dc.relation | TA7.C6 CER 59-45 | |
dc.relation.ispartof | Civil Engineering Reports | |
dc.relation.ispartof | CER, 59-45 | |
dc.rights | Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright. | |
dc.subject | Flow meters -- Testing | |
dc.subject | Flow meters -- Evaluation | |
dc.subject | Hydraulic engineering | |
dc.subject | Rotors -- Design and construction | |
dc.title | Evaluation of the performance of the floating rotor design flowmeter manufactured by the Pottermeter Company: flowmeter model 2-353A | |
dc.type | Text | |
dcterms.rights.dpla | This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s). |