Repository logo
 

Comparison of direct shear and triaxial tests for measurement of shear strength of sand

dc.contributor.authorRahman, Jamshed, author
dc.contributor.authorNelson, John D., advisor
dc.contributor.authorSiller, Thomas J., committee member
dc.contributor.authorMielke, Paul W., committee member
dc.date.accessioned2022-03-02T21:33:15Z
dc.date.available2022-03-02T21:33:15Z
dc.date.issued1991
dc.description.abstractTo ascertain the shear strength parameters of soils for engineering purposes is fundamental to soil mechanics and basic for designing earth-bearing and earth-retaining structures. Direct shear and triaxial tests are the most popular laboratory methods to determine these parameters. The direct shear test is used widely because it is simple and quick. The test has several disadvantages, however. The non-uniform stress-strain behavior, the rotation of principal planes during the test, and the imposition of the failure plane are chief among them. The triaxial test was designed as a possible alternative that eliminates some of these disadvantages. Direct shear test results are always comparable to those of the triaxial test; the difference usually is negligible from a practical point of view. Researchers have tried to unfold the intricacies involved in the direct shear test especially the complicated stress-strain behavior that a soil experiences during this test. Data, however, are lacking that determine the difference and establish a correlation between the results of the two tests. This study compares the two tests for measurement of shear strength parameters of sand. Triaxial and direct shear tests were performed on silica sand under the same density and normal stress conditions. Five sets of triaxial tests and 20 direct shear tests each were performed using four different makes of direct shear machines. The results of the direct shear tests were compared with those of the triaxial tests considering the latter as benchmarks. The possible effect of the structural features of the direct shear equipment on results was briefly studied. The results showed that the shear strengths from direct shear tests are higher than those from the triaxial tests. All four direct shear machines gave cohesion values different from each other and higher than the benchmark value. The Soiltest and Wykeham Farrance machines gave almost the same friction angle that was higher than the benchmark value by 4 degrees. The friction angle value from the ELE machine was higher by 2.7 degrees while those from Clockhouse machine were lower by 4.5 degrees as compared to the benchmark value.
dc.format.mediummasters theses
dc.identifier.urihttps://hdl.handle.net/10217/234490
dc.languageEnglish
dc.language.isoeng
dc.publisherColorado State University. Libraries
dc.relationCatalog record number (MMS ID): 991017636279703361
dc.relationTA710.5.R325
dc.relation.ispartof1980-1999
dc.rightsCopyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.
dc.subject.lcshShear strength of soils
dc.subject.lcshSoil mechanics
dc.titleComparison of direct shear and triaxial tests for measurement of shear strength of sand
dc.typeText
dcterms.rights.dplaThis Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
thesis.degree.disciplineCivil Engineering
thesis.degree.grantorColorado State University
thesis.degree.levelMasters
thesis.degree.nameMaster of Science (M.S.)

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ETDF_Rahman_Jamshed_1991_Spring_DIP.pdf
Size:
24.78 MB
Format:
Adobe Portable Document Format