Repository logo
 

Improved detection of radioactive material using a series of measurements

Date

2016

Authors

Mann, Jenelle, author
Brandl, Alexander, advisor
Johnson, Thomas, committee member
Kokoszka, Piotr, committee member
Leary, Del, committee member

Journal Title

Journal ISSN

Volume Title

Abstract

The goal of this project is to develop improved algorithms for detection of radioactive sources that have low signal compared to background. The detection of low signal sources is of interest in national security applications where the source may have weak ionizing radiation emissions, is heavily shielded, or the counting time is short (such as portal monitoring). Traditionally to distinguish signal from background the decision threshold (y*) is calculated by taking a long background count and limiting the false negative error (α error) to 5%. Some problems with this method include: background is constantly changing due to natural environmental fluctuations and large amounts of data are being taken as the detector continuously scans that are not utilized. Rather than looking at a single measurement, this work investigates looking at a series of N measurements and develops an appropriate decision threshold for exceeding the decision threshold n times in a series of N. This methodology is investigated for a rectangular, triangular, sinusoidal, Poisson, and Gaussian distribution.

Description

Rights Access

Subject

Citation

Associated Publications