Repository logo
 

Investigation of exposure rate discrepancies between energy compensated Geiger Mueller tubes and pressurized ionization chambers due to muon and anti-muon cosmic particles

dc.contributor.authorGift, Matthew, author
dc.contributor.authorJohnson, Thomas E., advisor
dc.contributor.authorBrandl, Alexander, committee member
dc.contributor.authorFisher, Gwenith, committee member
dc.date.accessioned2017-09-14T16:06:45Z
dc.date.available2017-09-14T16:06:45Z
dc.date.issued2017
dc.description.abstractEnergy compensated Geiger Mueller (GM) tubes and pressurized ionization chambers are two types of gas filled detectors that measure radiation dose or exposure but operate on different physical principles. Energy compensated GMs are gaining popularity because they are less expensive and more durable than pressurized ionization chambers, however, an exposure rate discrepancy may exist between the two instruments. At an elevation of about 1524m (5,000 ft), energy compensated GM tubes were observed to have nearly a 2-fold over-response to background measurements when compared to measurements performed by pressurized ionization chambers. The goal of this research is to investigate the expected exposure rate discrepancy due to muon and anti-muon cosmic particles, since they are the largest background contributor to dose at low elevations. Theoretically calculated average chord length and stopping power, as well as, Monte Carlo N-Particle 6 were used to investigate and characterize the exposure rate from muons and anti-muons. The calculated exposure rate contribution of muons and anti-muons for the background measurement of the energy compensated GM tube was negligible and is not expected to be the primary cause for the over-response. More research is needed to characterize the discrepancy.
dc.format.mediumborn digital
dc.format.mediummasters theses
dc.identifierGift_colostate_0053N_14411.pdf
dc.identifier.urihttps://hdl.handle.net/10217/184035
dc.languageEnglish
dc.language.isoeng
dc.publisherColorado State University. Libraries
dc.relation.ispartof2000-2019
dc.rightsCopyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.
dc.titleInvestigation of exposure rate discrepancies between energy compensated Geiger Mueller tubes and pressurized ionization chambers due to muon and anti-muon cosmic particles
dc.typeText
dcterms.rights.dplaThis Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
thesis.degree.disciplineEnvironmental and Radiological Health Sciences
thesis.degree.grantorColorado State University
thesis.degree.levelMasters
thesis.degree.nameMaster of Science (M.S.)

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Gift_colostate_0053N_14411.pdf
Size:
1.55 MB
Format:
Adobe Portable Document Format