Repository logo
 

Micron-size zero-valent iron emplacement in porous media using polymer additives: column and flow cell experiments

dc.contributor.authorOostrom, M., author
dc.contributor.authorWietsma, T. W., author
dc.contributor.authorCovert, M. A., author
dc.contributor.authorVermeul, V. R., author
dc.contributor.authorColorado State University, publisher
dc.date.accessioned2020-01-30T15:47:37Z
dc.date.available2020-01-30T15:47:37Z
dc.date.issued2006
dc.description2006 annual AGU hydrology days was held at Colorado State University on March 20 - March 22, 2006.
dc.descriptionIncludes bibliographical references.
dc.description.abstractAt the Hanford Site, an extensive In Situ Redox Manipulation (ISRM) permeable reactive barrier was installed to prevent chromate from reaching the Columbia River. However, chromium has been detected in several wells, indicating a premature loss of the reductive capacity in the aquifer. Laboratory experiments have been conducted to investigate whether barrier reductive capacity can be enhanced by adding micron-scale zero-valent iron to the high-permeability zones within the aquifer using shear-thinning fluids containing polymers. Porous media were packed in a wedge-shaped flow cell to create either a heterogeneous layered system with a high-permeability zone be-tween two low-permeability zones or a high-permeability channel surrounded by low-permeability materials. The injection flow rate, polymer type, polymer concentration, and injected pore volumes were determined based on preliminary short- and long-column experiments. The flow cell experiments indicated that iron concentration enhancements of at least 0.6% (w/w) could be obtained using moderate flow rates and injection of 30 pore volumes. The 0.6% amended Fe0 concentration would provide approximately 20 times the average reductive capacity that is provided by the dithionite-reduced iron in the ISRM barrier. Calculations show that a 1-m-long Fe0 amended zone with an average concentration of 0.6% w/w iron subject to a groundwater velocity of 1 m/day will have an estimated longevity of 7.2 years.
dc.format.mediumborn digital
dc.format.mediumproceedings (reports)
dc.identifier.urihttps://hdl.handle.net/10217/200631
dc.identifier.urihttp://dx.doi.org/10.25675/10217/200631
dc.languageEnglish
dc.language.isoeng
dc.publisherColorado State University. Libraries
dc.relation.ispartofHydrology Days
dc.rightsCopyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.
dc.titleMicron-size zero-valent iron emplacement in porous media using polymer additives: column and flow cell experiments
dc.title.alternativeHydrology days 2006
dc.title.alternativeAGU hydrology days 2006
dc.typeText

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
CONF_HydroDays_OostromEtal2_2006.pdf
Size:
319.82 KB
Format:
Adobe Portable Document Format