Repository logo
 

Efficiency modeling for neutron detectors

dc.contributor.authorScallan, Lisa Marie, author
dc.contributor.authorBrandl, Alex, advisor
dc.contributor.authorJohnson, Thomas, committee member
dc.contributor.authorChen, Suren, committee member
dc.date.accessioned2007-01-03T06:42:47Z
dc.date.available2007-01-03T06:42:47Z
dc.date.issued2014
dc.description.abstractNeutron detectors are used for various applications, such as for workplace monitoring in a neutron field, during nuclear incidents, and for the detection of contraband nuclear material. The Remote Sensing Laboratory has developed and employed several neutron detector designs, and characterization data have been collected with these detectors under varying environmental conditions. Using MCNP/MCNPX the neutron fluence rate and dose rate were evaluated during open-field deployment as a function of moisture content in air and soil, barometric pressure, and varying pavement and soil composition. The focus of this analysis was on the incident neutron spectra, detector efficiency and count rate at the detector location. The most prevalent parameters directly contributing to scattered neutrons into the active detector volume were evaluated. Experimentally observed functional dependence on the source-detector distance was compared to MCNP/MCNPX simulation data. This study provides detector efficiency data for a wide range of operational conditions beyond the current capacity for experimental detector characterization.
dc.format.mediumborn digital
dc.format.mediummasters theses
dc.identifierScallan_colostate_0053N_12534.pdf
dc.identifier.urihttp://hdl.handle.net/10217/84139
dc.languageEnglish
dc.language.isoeng
dc.publisherColorado State University. Libraries
dc.relation.ispartof2000-2019
dc.rightsCopyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.
dc.subjectdetector
dc.subjectradiation
dc.subjectneutron
dc.titleEfficiency modeling for neutron detectors
dc.typeText
dcterms.rights.dplaThis Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
thesis.degree.disciplineEnvironmental and Radiological Health Sciences
thesis.degree.grantorColorado State University
thesis.degree.levelMasters
thesis.degree.nameMaster of Science (M.S.)

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Scallan_colostate_0053N_12534.pdf
Size:
1.12 MB
Format:
Adobe Portable Document Format
Description: