Repository logo
 

Application of structural health monitoring for damage identification in an industrial fan rotor using in-situ modal analysis testing

dc.contributor.authorWilcox, Chad M., author
dc.contributor.authorWillson, Bryan D., advisor
dc.contributor.authorAlciatore, David G., committee member
dc.contributor.authorBienkiewicz, Bogusz J., committee member
dc.date.accessioned2007-01-03T06:51:11Z
dc.date.available2007-01-03T06:51:11Z
dc.date.issued2014
dc.description.abstractA testing procedure is desired which can be applied in manufacturing environments to determine the structural integrity of rotating components within a machine. Current non-destructive evaluation (NDE) of components includes visual inspection, dye penetrant, and x-ray testing. Each of these NDE techniques have limitations in manufacturing plants given very limited time frames and access to rotating components. Vibration condition monitoring is widely used and accepted as a beneficial way to determine faults in rotating equipment. Current vibration condition monitoring practices rely on measurement and analysis of response data. The response data is affected by both changing forces and structural parameters of the system being measured. Therefore, determining whether forces have changed or the structure has been compromised is not readily determined from vibration condition monitoring data. Structural health monitoring (SHM) has been implemented for a variety of structural faults including: cracking and breaking, loosening of assembled parts, flaws and voids caused by manufacturing, and improper assembly of parts (Wolff & Richardson, 1989). Many studies in the area of SHM have focused on idealized test setups and have used only simulated data. This study focuses on implementation of SHM on the rotating assembly of an industrial fan. The data and results from SHM are used to validate whether or not the structure has been compromised.
dc.format.mediumborn digital
dc.format.mediummasters theses
dc.identifierWilcox_colostate_0053N_12521.pdf
dc.identifier.urihttp://hdl.handle.net/10217/84575
dc.languageEnglish
dc.language.isoeng
dc.publisherColorado State University. Libraries
dc.relation.ispartof2000-2019
dc.rightsCopyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.
dc.subjectcondition monitoring
dc.subjectfan
dc.subjectmodal analysis
dc.subjectNTD
dc.subjectstructural health monitoring
dc.subjectvibration analysis
dc.titleApplication of structural health monitoring for damage identification in an industrial fan rotor using in-situ modal analysis testing
dc.typeText
dcterms.rights.dplaThis Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
thesis.degree.disciplineMechanical Engineering
thesis.degree.grantorColorado State University
thesis.degree.levelMasters
thesis.degree.nameMaster of Science (M.S.)

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Wilcox_colostate_0053N_12521.pdf
Size:
4.12 MB
Format:
Adobe Portable Document Format
Description: