Repository logo
 

Final report Lake Adair project: model study for hollow-cone valve outlet box

Date

1968-09

Authors

Mercer, Albert G., author
Civil Engineering Department, Colorado State University, publisher

Journal Title

Journal ISSN

Volume Title

Abstract

Subsequent to the hydraulic mode l study reported herein, several changes have been made in the detailed design and concept of this project. The most pertinent is the reduction of the diameter of the hollow-cone valve from 36 inches to 30 inches. This change reduces the capacity of the outlet works from 400 cfs to 230 cfs. However, the final geometry tested will still be satisfactory as long as the location of the apex of the valve cone remains the same with respect to the baffle walls, so that the trajectories intercepted by the surrounding chamber walls remain unaltered. Another change involving the outlet works is the reduction of the capacity of the bypass from 170 cfs to 750 cfs. This change is minor, however, and need not affect the chamber dimensions.

Description

CER68-69AGM20.
September 1968.
Submitted to Tipton and Kalmbach, Inc., Denver, Colorado.

Rights Access

Subject

Hydrologic models
Valves

Citation

Associated Publications