Styles, Stuart, authorU.S. Committee on Irrigation and Drainage, publisher2020-04-012020-04-012005https://hdl.handle.net/10217/201691Presented during the Third international conference on irrigation and drainage held March 30 - April 2, 2005 in San Diego, California. The theme of the conference was "Water district management and governance."This paper summarizes the results of a performance evaluation using advanced hydroacoustic rating techniques in irrigation canal systems. Standardized field-tested procedures and technical specifications for index velocity ratings have been developed for rating measurement locations using hydroacoustic flow meters. Water managers and users of advanced electronic flow measuring devices can improve the cost effectiveness, accuracy, and quality control of discharge records, even at sites with complex flow conditions, by observing these recommended guidelines.born digitalCD-ROMsproceedings (reports)engCopyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.flow measurementnon-standard structurehydroacoustic flow meterindex velocity ratingNon-standard structure flow measurement evaluation using the flow rate indexing procedure - QIPFlow rate indexing procedure - QIPText