Repository logo
 

Evaluation of the performance of the floating rotor design flowmeter manufactured by the Pottermeter Company: flowmeter model 2-353A

Date

1959-09

Authors

Karaki, Susumu, author
Videon, Fred, author
Colorado State University Research Foundation, publisher

Journal Title

Journal ISSN

Volume Title

Abstract

This report presents an evaluation of the performance of a Pottermeter Model 2-353A. The original meter tested was found to give erratic results due largely to the formation of a vapor pocket at the stationary cone. The meter was redesigned by the Pottermeter Company and the results of tests of the revised meter showed improvement in performance characteristics. Tests for head loss and pressure distribution through the meter were also made and are reported herein.

Description

CER59SSK45.
September 1959.
Conducted for the Martin Company, Denver Division, Denver, Colorado through Colorado State University Research Foundation, Civil Engineering Section, Fort Collins, Colorado.

Rights Access

Subject

Flow meters -- Testing
Flow meters -- Evaluation
Hydraulic engineering
Rotors -- Design and construction

Citation

Associated Publications