53 2110
McCluskey, Christina; Hill, Tom; DeMott, Paul; 
Colorado State University, Department of Atmospheric Science, 3915 West Laporte Ave., Fort Collins, CO, 80521, USA
Ice Spectrometer (IS)
BACCHUS Mace Head Observatory Ice Nucleation Project
1     1 
2015, 08, 27, 2016, 11, 10
0 
TempC[],degC, Temperature_array
start_time, fraction of UTC DATE given on line 7 
3 ; {Number of primary variables}
1,1,1
-9999,-9999,-9999
N_INP[], number per standard litre of air, INP_STP_NumDensity_array
CL_INP_LOWER[], Upper 95% conf. interval for # of INP per standard litre of air, 95%_Conf_interval_lower_array
CL_INP_UPPER[], Upper 95% conf. interval for # of INP per standard litre of air, 95%_Conf_interval_upper_array
9 ; {Number of auxiliary variables} 
1,1,1,1,1,1,1,1
-9999,-9999,-9999,-9999,-9999,-9999,-9999,-9999,-9999 
end_date_year 
end_date_month 
end_date_day 
end_time, fraction of day in UTC, end of sample period
start_Lat, degrees, Latitude
start_Lon, degrees, Longitude
end_Lat, degrees, Latitude
end_Long, degrees, Longitude
elevation, meters
0
25
PI_CONTACT_INFO: +1 970 491 7484, CSU, mccluscs@atmos.colostate.edu
PLATFORM: Mace Head Observatory
LOCATION: Lat, lon of start and end points given as auxiliary variables; all at 10 meters elevation
INSTRUMENT_INFO: Colorado State University Ice Spectrometer
UNCERTAINTY: INP 95% confidence intervals given as variable
ULOD_FLAG: -7777
ULOD_VALUE: N/A
LLOD_FLAG:  -8888
LLOD_VALUE: N/A
DM_CONTACT_INFO: N/A
PROJECT_INFO: BACCHUS Mace Head field campaign
STIPULATIONS_ON_USE: Use of these data requires PRIOR OK from the PI.
OTHER_COMMENTS: 
0.05 um pore diameter, 47 mm polycarbonate Nuclepore filter sample, with average flow rate 10 Lpm (STP).
Filter shaken in 6 mL of 0.02 um filtered deioinised water (Anotop) for 20 min. 
Dilutions (15-fold) were made in 0.02 um filtered deionised water.
Immersion freezing performed at -0.3 K min-1.
INP per mL were derived using 32 wells, each containing 50 microlitres of re-suspension solution.
Confidence intervals for INP are expressed in the same units as the number of INP.
They are binomial sampling confidence intervals (95%) derived using the formula (No. 2) recommended by Agresti and Coull (1998).
Data is final, corrected for instrument background and for sampling contamination determined from blank filters (n=7).
REVISION: R1
R1: Final data
start_time, end_date_year, end_date_month, end_date_day, end_time, start_lat, start_lon, end_lat, end_lon, elevation
0.57153, 2015, 08, 28, 0.48056, 53.32, -9.90, 53.32, -9.90, 10.0
-16.2	0.00007	0.00006	0.00030
-16.5	0.00037	0.00027	0.00091
-17.0	0.00066	0.00044	0.00120
-17.2	0.00098	0.00061	0.00144
-17.5	0.00131	0.00076	0.00164
-17.7	0.00166	0.00092	0.00182
-18.0	0.00162	0.00090	0.00178
-18.5	0.00155	0.00086	0.00171
-19.0	0.00312	0.00147	0.00242
-19.5	0.00317	0.00150	0.00245
-20.0	0.00372	0.00171	0.00269
-20.5	0.00469	0.00205	0.00304
-21.0	0.00882	0.00348	0.00454
-21.5	0.00958	0.00375	0.00480
-22.0	0.01088	0.00434	0.00545
-22.5	0.01526	0.00611	0.00725
-23.0	0.01963	0.00828	0.00946
-23.5	0.06598	0.03140	0.05037
-24.0	0.06892	0.03287	0.05243
-24.5	0.09327	0.04234	0.06272
-25.0	0.13138	0.05636	0.07686
-25.5	0.14612	0.06186	0.08231
-26.0	0.21960	0.09444	0.11667
-26.5	0.29370	0.12998	0.15225
-27.0	0.43349	0.22463	0.25006