McCluskey, Christina; Hill, Tom; DeMott, Paul; 
Colorado State University, Department of Atmospheric Science, 3915 West Laporte Ave., Fort Collins, CO, 80521, USA
Ice Spectrometer (IS)
BACCHUS Mace Head Observatory Ice Nucleation Project
1     1 
2015, 08, 23, 2016, 11, 10
0 
TempC[],degC, Temperature_array
start_time, fraction of UTC DATE given on line 7 
3 ; {Number of primary variables}
1,1,1
-9999,-9999,-9999
N_INP[], number per standard litre of air, INP_STP_NumDensity_array
CL_INP_LOWER[], Upper 95% conf. interval for # of INP per standard litre of air, 95%_Conf_interval_lower_array
CL_INP_UPPER[], Upper 95% conf. interval for # of INP per standard litre of air, 95%_Conf_interval_upper_array
9 ; {Number of auxiliary variables} 
1,1,1,1,1,1,1,1
-9999,-9999,-9999,-9999,-9999,-9999,-9999,-9999,-9999 
end_date_year 
end_date_month 
end_date_day 
end_time, fraction of day in UTC, end of sample period
start_Lat, degrees, Latitude
start_Lon, degrees, Longitude
end_Lat, degrees, Latitude
end_Long, degrees, Longitude
elevation, meters
0
25
PI_CONTACT_INFO: +1 970 491 7484, CSU, mccluscs@atmos.colostate.edu
PLATFORM: Mace Head Observatory
LOCATION: Lat, lon of start and end points given as auxiliary variables; all at 10 meters elevation
INSTRUMENT_INFO: Colorado State University Ice Spectrometer
UNCERTAINTY: INP 95% confidence intervals given as variable
ULOD_FLAG: -7777
ULOD_VALUE: N/A
LLOD_FLAG:  -8888
LLOD_VALUE: N/A
DM_CONTACT_INFO: N/A
PROJECT_INFO: BACCHUS Mace Head field campaign
STIPULATIONS_ON_USE: Use of these data requires PRIOR OK from the PI.
OTHER_COMMENTS: 
0.05 um pore diameter, 47 mm polycarbonate Nuclepore filter sample, with average flow rate 10 Lpm (STP).
Filter shaken in 6 mL of 0.02 um filtered deioinised water (Anotop) for 20 min. 
Dilutions (15-fold) were made in 0.02 um filtered deionised water.
Immersion freezing performed at -0.3 K min-1.
INP per mL were derived using 32 wells, each containing 50 microlitres of re-suspension solution.
Confidence intervals for INP are expressed in the same units as the number of INP.
They are binomial sampling confidence intervals (95%) derived using the formula (No. 2) recommended by Agresti and Coull (1998).
Data is final, corrected for instrument background and for sampling contamination determined from blank filters (n=7).
REVISION: R1
R1: Final data
start_time, end_date_year, end_date_month, end_date_day, end_time, start_lat, start_lon, end_lat, end_lon, elevation
0.39722, 2015, 08, 24, 0.40903, 53.32, -9.90, 53.32, -9.90, 10.0
-11.0	0.00083	0.00069	0.00365
-11.5	0.00080	0.00066	0.00354
-11.7	0.00079	0.00065	0.00348
-12.0	0.00077	0.00064	0.00340
-12.5	0.00074	0.00061	0.00324
-13.0	0.00070	0.00057	0.00306
-13.5	0.00168	0.00122	0.00417
-13.7	0.00166	0.00121	0.00412
-14.0	0.00162	0.00118	0.00403
-14.5	0.00156	0.00113	0.00387
-15.0	0.00148	0.00108	0.00368
-15.2	0.00145	0.00106	0.00360
-15.5	0.00139	0.00102	0.00346
-16.0	0.00235	0.00157	0.00428
-16.1	0.00457	0.00266	0.00571
-16.3	0.00453	0.00263	0.00565
-16.5	0.00448	0.00260	0.00559
-16.7	0.00561	0.00309	0.00615
-17.0	0.00452	0.00263	0.00564
-17.3	0.00340	0.00210	0.00497
-17.5	0.00333	0.00206	0.00487
-18.0	0.00438	0.00255	0.00544
-18.5	0.00437	0.00255	0.00542
-19.0	0.00411	0.00240	0.00510
-19.5	0.00381	0.00222	0.00473
-20.0	0.00369	0.00215	0.00456
-20.5	0.00766	0.00389	0.00682
-21.0	0.00934	0.00459	0.00765
-21.5	0.01897	0.00819	0.01164
-22.0	0.02741	0.01160	0.01544
-22.5	0.05075	0.02170	0.02590
-23.0	0.09194	0.04617	0.05069
-23.5	0.08792	0.04506	0.04991
-25.0	0.20342	0.10932	0.19084
-25.5	0.33615	0.16458	0.24742
-26.0	0.42559	0.20566	0.29283
-26.2	0.68731	0.32460	0.41299
-26.5	0.98377	0.49238	0.58604