53 2110
McCluskey, Christina; Hill, Tom; DeMott, Paul; 
Colorado State University, Department of Atmospheric Science, 3915 West Laporte Ave., Fort Collins, CO, 80521, USA
Ice Spectrometer (IS)
BACCHUS Mace Head Observatory Ice Nucleation Project
1     1 
2015, 08, 19, 2016, 11, 10
0 
TempC[],degC, Temperature_array
start_time, fraction of UTC DATE given on line 7 
3 ; {Number of primary variables}
1,1,1
-9999,-9999,-9999
N_INP[], number per standard litre of air, INP_STP_NumDensity_array
CL_INP_LOWER[], Upper 95% conf. interval for # of INP per standard litre of air, 95%_Conf_interval_lower_array
CL_INP_UPPER[], Upper 95% conf. interval for # of INP per standard litre of air, 95%_Conf_interval_upper_array
9 ; {Number of auxiliary variables} 
1,1,1,1,1,1,1,1
-9999,-9999,-9999,-9999,-9999,-9999,-9999,-9999,-9999 
end_date_year 
end_date_month 
end_date_day 
end_time, fraction of day in UTC, end of sample period
start_Lat, degrees, Latitude
start_Lon, degrees, Longitude
end_Lat, degrees, Latitude
end_Long, degrees, Longitude
elevation, meters
0
25
PI_CONTACT_INFO: +1 970 491 7484, CSU, mccluscs@atmos.colostate.edu
PLATFORM: Mace Head Observatory
LOCATION: Lat, lon of start and end points given as auxiliary variables; all at 10 meters elevation
INSTRUMENT_INFO: Colorado State University Ice Spectrometer
UNCERTAINTY: INP 95% confidence intervals given as variable
ULOD_FLAG: -7777
ULOD_VALUE: N/A
LLOD_FLAG:  -8888
LLOD_VALUE: N/A
DM_CONTACT_INFO: N/A
PROJECT_INFO: BACCHUS Mace Head field campaign
STIPULATIONS_ON_USE: Use of these data requires PRIOR OK from the PI.
OTHER_COMMENTS: 
0.05 um pore diameter, 47 mm polycarbonate Nuclepore filter sample, with average flow rate 10 Lpm (STP).
Filter shaken in 6 mL of 0.02 um filtered deioinised water (Anotop) for 20 min. 
Dilutions (15-fold) were made in 0.02 um filtered deionised water.
Immersion freezing performed at -0.3 K min-1.
INP per mL were derived using 32 wells, each containing 50 microlitres of re-suspension solution.
Confidence intervals for INP are expressed in the same units as the number of INP.
They are binomial sampling confidence intervals (95%) derived using the formula (No. 2) recommended by Agresti and Coull (1998).
Data is final, corrected for instrument background and for sampling contamination determined from blank filters (n=7).
REVISION: R1
R1: Final data
start_time, end_date_year, end_date_month, end_date_day, end_time, start_lat, start_lon, end_lat, end_lon, elevation
0.51786, 2015, 08, 20, 0.48333, 53.32, -9.90, 53.32, -9.90, 10.0
-8.5	0.00024	0.00020	0.00108
-10.0	0.00051	0.00037	0.00126
-10.6	0.00078	0.00052	0.00142
-10.8	0.00108	0.00066	0.00158
-11.0	0.00107	0.00066	0.00157
-11.3	0.00107	0.00066	0.00157
-11.5	0.00137	0.00080	0.00171
-11.7	0.00168	0.00093	0.00185
-12.0	0.00200	0.00106	0.00198
-12.2	0.00200	0.00105	0.00197
-12.5	0.00200	0.00105	0.00197
-13.0	0.00255	0.00127	0.00220
-13.5	0.00459	0.00197	0.00292
-14.0	0.00457	0.00197	0.00291
-14.5	0.00608	0.00247	0.00341
-15.0	0.00726	0.00286	0.00380
-15.5	0.00790	0.00307	0.00402
-16.0	0.00860	0.00331	0.00425
-16.5	0.00923	0.00355	0.00451
-17.0	0.00906	0.00351	0.00448
-17.5	0.01088	0.00418	0.00514
-18.0	0.01476	0.00573	0.00670
-18.5	0.01657	0.00655	0.00751
-19.0	0.02202	0.00950	0.01050
-19.5	0.02165	0.00942	0.01045
-20.0	0.02735	0.01309	0.01412
-20.5	0.02709	0.01302	0.01406
-21.0	0.01331	0.00887	0.02397
-21.5	0.01602	0.01027	0.02566
-22.0	0.02675	0.01518	0.03086
-22.5	0.03007	0.01665	0.03257
-23.0	0.03119	0.01729	0.03368
-23.5	0.04410	0.02247	0.03900
-24.0	0.05850	0.02790	0.04450
-24.5	0.07235	0.03318	0.05011
-25.0	0.09444	0.04215	0.06012
-25.5	0.18171	0.07945	0.09919
-26.0	0.27735	0.13462	0.15731
-26.5	0.35279	0.18843	0.21289