53 2110
McCluskey, Christina; Hill, Tom; DeMott, Paul; 
Colorado State University, Department of Atmospheric Science, 3915 West Laporte Ave., Fort Collins, CO, 80521, USA
Ice Spectrometer (IS)
BACCHUS Mace Head Observatory Ice Nucleation Project
1     1 
2015, 08, 17, 2016, 11, 10
0 
TempC[],degC, Temperature_array
start_time, fraction of UTC DATE given on line 7 
3 ; {Number of primary variables}
1,1,1
-9999,-9999,-9999
N_INP[], number per standard litre of air, INP_STP_NumDensity_array
CL_INP_LOWER[], Upper 95% conf. interval for # of INP per standard litre of air, 95%_Conf_interval_lower_array
CL_INP_UPPER[], Upper 95% conf. interval for # of INP per standard litre of air, 95%_Conf_interval_upper_array
9 ; {Number of auxiliary variables} 
1,1,1,1,1,1,1,1
-9999,-9999,-9999,-9999,-9999,-9999,-9999,-9999,-9999 
end_date_year 
end_date_month 
end_date_day 
end_time, fraction of day in UTC, end of sample period
start_Lat, degrees, Latitude
start_Lon, degrees, Longitude
end_Lat, degrees, Latitude
end_Long, degrees, Longitude
elevation, meters
0
25
PI_CONTACT_INFO: +1 970 491 7484, CSU, mccluscs@atmos.colostate.edu
PLATFORM: Mace Head Observatory
LOCATION: Lat, lon of start and end points given as auxiliary variables; all at 10 meters elevation
INSTRUMENT_INFO: Colorado State University Ice Spectrometer
UNCERTAINTY: INP 95% confidence intervals given as variable
ULOD_FLAG: -7777
ULOD_VALUE: N/A
LLOD_FLAG:  -8888
LLOD_VALUE: N/A
DM_CONTACT_INFO: N/A
PROJECT_INFO: BACCHUS Mace Head field campaign
STIPULATIONS_ON_USE: Use of these data requires PRIOR OK from the PI.
OTHER_COMMENTS: 
0.05 um pore diameter, 47 mm polycarbonate Nuclepore filter sample, with average flow rate 10 Lpm (STP).
Filter shaken in 6 mL of 0.02 um filtered deioinised water (Anotop) for 20 min. 
Dilutions (15-fold) were made in 0.02 um filtered deionised water.
Immersion freezing performed at -0.3 K min-1.
INP per mL were derived using 32 wells, each containing 50 microlitres of re-suspension solution.
Confidence intervals for INP are expressed in the same units as the number of INP.
They are binomial sampling confidence intervals (95%) derived using the formula (No. 2) recommended by Agresti and Coull (1998).
Data is final, corrected for instrument background and for sampling contamination determined from blank filters (n=7).
REVISION: R1
R1: Final data
start_time, end_date_year, end_date_month, end_date_day, end_time, start_lat, start_lon, end_lat, end_lon, elevation
0.44097, 2015, 08, 18, 0.44097, 53.32, -9.90, 53.32, -9.90, 10.0
-11.5	0.00023	0.00019	0.00101
-11.6	0.00083	0.00055	0.00151
-12.0	0.00372	0.00171	0.00271
-12.5	0.00561	0.00234	0.00334
-13.0	0.01358	0.00511	0.00612
-13.5	0.02482	0.01048	0.01149
-11.7	0.00422	0.00348	0.01856
-12.0	0.00422	0.00348	0.01854
-12.5	0.00421	0.00347	0.01849
-13.0	0.00419	0.00346	0.01844
-13.5	0.00418	0.00345	0.01838
-13.8	0.00859	0.00627	0.02136
-14.0	0.00859	0.00626	0.02135
-14.5	0.00857	0.00625	0.02130
-15.0	0.00855	0.00623	0.02124
-15.2	0.01311	0.00872	0.02382
-15.5	0.01782	0.01102	0.02615
-15.7	0.02271	0.01321	0.02836
-16.0	0.02270	0.01320	0.02834
-16.3	0.02268	0.01318	0.02832
-16.5	0.02775	0.01531	0.03046
-17.0	0.03300	0.01739	0.03254
-17.5	0.03295	0.01736	0.03249
-18.0	0.03840	0.01942	0.03456
-18.5	0.03834	0.01939	0.03450
-19.0	0.05627	0.02577	0.04092
-19.5	0.06276	0.02797	0.04311
-20.0	0.06266	0.02793	0.04304
-20.5	0.07674	0.03262	0.04774
-21.0	0.07232	0.03152	0.04706
-21.5	0.08804	0.03676	0.05231
-22.0	0.08784	0.03668	0.05220
-22.8	0.09173	0.03843	0.05437
-23.0	0.10092	0.04153	0.05748
-23.5	0.13310	0.05254	0.06853
-24.0	0.15045	0.06031	0.07735
-24.5	0.18935	0.07869	0.09766
-25.0	0.28219	0.12176	0.14078