53 2110
McCluskey, Christina; Hill, Tom; DeMott, Paul; 
Colorado State University, Department of Atmospheric Science, 3915 West Laporte Ave., Fort Collins, CO, 80521, USA
Ice Spectrometer (IS)
BACCHUS Mace Head Observatory Ice Nucleation Project
1     1 
2015, 08, 16, 2016, 11, 10
0 
TempC[],degC, Temperature_array
start_time, fraction of UTC DATE given on line 7 
3 ; {Number of primary variables}
1,1,1
-9999,-9999,-9999
N_INP[], number per standard litre of air, INP_STP_NumDensity_array
CL_INP_LOWER[], Upper 95% conf. interval for # of INP per standard litre of air, 95%_Conf_interval_lower_array
CL_INP_UPPER[], Upper 95% conf. interval for # of INP per standard litre of air, 95%_Conf_interval_upper_array
9 ; {Number of auxiliary variables} 
1,1,1,1,1,1,1,1
-9999,-9999,-9999,-9999,-9999,-9999,-9999,-9999,-9999 
end_date_year 
end_date_month 
end_date_day 
end_time, fraction of day in UTC, end of sample period
start_Lat, degrees, Latitude
start_Lon, degrees, Longitude
end_Lat, degrees, Latitude
end_Long, degrees, Longitude
elevation, meters
0
25
PI_CONTACT_INFO: +1 970 491 7484, CSU, mccluscs@atmos.colostate.edu
PLATFORM: Mace Head Observatory
LOCATION: Lat, lon of start and end points given as auxiliary variables; all at 10 meters elevation
INSTRUMENT_INFO: Colorado State University Ice Spectrometer
UNCERTAINTY: INP 95% confidence intervals given as variable
ULOD_FLAG: -7777
ULOD_VALUE: N/A
LLOD_FLAG:  -8888
LLOD_VALUE: N/A
DM_CONTACT_INFO: N/A
PROJECT_INFO: BACCHUS Mace Head field campaign
STIPULATIONS_ON_USE: Use of these data requires PRIOR OK from the PI.
OTHER_COMMENTS: 
0.05 um pore diameter, 47 mm polycarbonate Nuclepore filter sample, with average flow rate 10 Lpm (STP).
Filter shaken in 6 mL of 0.02 um filtered deioinised water (Anotop) for 20 min. 
Dilutions (15-fold) were made in 0.02 um filtered deionised water.
Immersion freezing performed at -0.3 K min-1.
INP per mL were derived using 32 wells, each containing 50 microlitres of re-suspension solution.
Confidence intervals for INP are expressed in the same units as the number of INP.
They are binomial sampling confidence intervals (95%) derived using the formula (No. 2) recommended by Agresti and Coull (1998).
Data is final, corrected for instrument background and for sampling contamination determined from blank filters (n=7).
REVISION: R1
R1: Final data
start_time, end_date_year, end_date_month, end_date_day, end_time, start_lat, start_lon, end_lat, end_lon, elevation
0.62083, 2015, 08, 17, 0.44097, 53.32, -9.90, 53.32, -9.90, 10.0
-11.4	0.00065	0.00047	0.00161
-11.5	0.00065	0.00047	0.00160
-11.8	0.00101	0.00067	0.00184
-12.0	0.00180	0.00105	0.00225
-12.2	0.00309	0.00157	0.00278
-12.5	0.00356	0.00173	0.00296
-12.8	0.00455	0.00209	0.00331
-13.0	0.00455	0.00208	0.00331
-13.2	0.00624	0.00265	0.00388
-13.5	0.00623	0.00265	0.00388
-13.8	0.00685	0.00285	0.00408
-14.0	0.00684	0.00285	0.00408
-14.2	0.00666	0.00281	0.00405
-14.5	0.00803	0.00326	0.00450
-15.0	0.00800	0.00325	0.00449
-15.5	0.00797	0.00323	0.00447
-15.7	0.01042	0.00405	0.00530
-16.0	0.01040	0.00405	0.00529
-16.5	0.01132	0.00436	0.00560
-17.0	0.01349	0.00512	0.00636
-17.5	0.01455	0.00555	0.00680
-18.0	0.01578	0.00605	0.00733
-18.5	0.01552	0.00599	0.00728
-19.0	0.01506	0.00589	0.00721
-19.5	0.01665	0.00653	0.00785
-20.0	0.01835	0.00730	0.00863
-20.5	0.02385	0.00989	0.01123
-21.0	0.03581	0.01714	0.01849
-21.5	0.04920	0.02547	0.04585
-22.0	0.05704	0.02844	0.04880
-22.5	0.05934	0.02962	0.05061
-23.0	0.10959	0.04770	0.06893
-23.5	0.13168	0.05585	0.07745
-24.0	0.17885	0.07294	0.09460
-24.5	0.23917	0.09788	0.12035
-25.0	0.29911	0.12614	0.14947
-25.5	0.33559	0.14754	0.17223
-26.0	0.32347	0.14512	0.17125
-26.5	0.49223	0.25365	0.28164