53 2110
McCluskey, Christina; Hill, Tom; DeMott, Paul; 
Colorado State University, Department of Atmospheric Science, 3915 West Laporte Ave., Fort Collins, CO, 80521, USA
Ice Spectrometer (IS)
BACCHUS Mace Head Observatory Ice Nucleation Project
1     1 
2015, 08, 11, 2016, 11, 10
0 
TempC[],degC, Temperature_array
start_time, fraction of UTC DATE given on line 7 
3 ; {Number of primary variables}
1,1,1
-9999,-9999,-9999
N_INP[], number per standard litre of air, INP_STP_NumDensity_array
CL_INP_LOWER[], Upper 95% conf. interval for # of INP per standard litre of air, 95%_Conf_interval_lower_array
CL_INP_UPPER[], Upper 95% conf. interval for # of INP per standard litre of air, 95%_Conf_interval_upper_array
9 ; {Number of auxiliary variables} 
1,1,1,1,1,1,1,1
-9999,-9999,-9999,-9999,-9999,-9999,-9999,-9999,-9999 
end_date_year 
end_date_month 
end_date_day 
end_time, fraction of day in UTC, end of sample period
start_Lat, degrees, Latitude
start_Lon, degrees, Longitude
end_Lat, degrees, Latitude
end_Long, degrees, Longitude
elevation, meters
0
25
PI_CONTACT_INFO: +1 970 491 7484, CSU, mccluscs@atmos.colostate.edu
PLATFORM: Mace Head Observatory
LOCATION: Lat, lon of start and end points given as auxiliary variables; all at 10 meters elevation
INSTRUMENT_INFO: Colorado State University Ice Spectrometer
UNCERTAINTY: INP 95% confidence intervals given as variable
ULOD_FLAG: -7777
ULOD_VALUE: N/A
LLOD_FLAG:  -8888
LLOD_VALUE: N/A
DM_CONTACT_INFO: N/A
PROJECT_INFO: BACCHUS Mace Head field campaign
STIPULATIONS_ON_USE: Use of these data requires PRIOR OK from the PI.
OTHER_COMMENTS: 
0.05 um pore diameter, 47 mm polycarbonate Nuclepore filter sample, with average flow rate 10 Lpm (STP).
Filter shaken in 6 mL of 0.02 um filtered deioinised water (Anotop) for 20 min. 
Dilutions (15-fold) were made in 0.02 um filtered deionised water.
Immersion freezing performed at -0.3 K min-1.
INP per mL were derived using 32 wells, each containing 50 microlitres of re-suspension solution.
Confidence intervals for INP are expressed in the same units as the number of INP.
They are binomial sampling confidence intervals (95%) derived using the formula (No. 2) recommended by Agresti and Coull (1998).
Data is final, corrected for instrument background and for sampling contamination determined from blank filters (n=7).
REVISION: R1
R1: Final data
start_time, end_date_year, end_date_month, end_date_day, end_time, start_lat, start_lon, end_lat, end_lon, elevation
0.56875, 2015, 08, 12, 0.82778, 53.32, -9.90, 53.32, -9.90, 10.0
-11.8	0.00017	0.00014	0.00075
-12.0	0.00017	0.00014	0.00074
-12.5	0.00038	0.00028	0.00095
-12.7	0.00061	0.00040	0.00111
-12.8	0.00061	0.00040	0.00110
-13.0	0.00060	0.00040	0.00110
-13.5	0.00059	0.00039	0.00108
-13.7	0.00083	0.00051	0.00121
-14.0	0.00082	0.00051	0.00120
-14.3	0.00081	0.00050	0.00119
-14.5	0.00105	0.00061	0.00131
-14.7	0.00104	0.00061	0.00130
-15.0	0.00103	0.00060	0.00129
-15.5	0.00154	0.00081	0.00152
-16.0	0.00152	0.00080	0.00149
-16.2	0.00151	0.00079	0.00148
-16.5	0.00206	0.00100	0.00171
-17.0	0.00264	0.00121	0.00192
-17.5	0.00404	0.00168	0.00241
-18.0	0.00420	0.00175	0.00249
-18.5	0.00459	0.00188	0.00262
-19.0	0.00559	0.00228	0.00306
-19.5	0.00612	0.00246	0.00324
-20.0	0.00716	0.00287	0.00368
-20.5	0.00958	0.00386	0.00471
-21.0	0.01197	0.00498	0.00586
-21.5	0.02124	0.01038	0.01128
-22.0	0.02110	0.01031	0.01120
-22.5	0.03624	0.01847	0.03204
-23.0	0.04184	0.02059	0.03416
-23.5	0.06074	0.02835	0.04306
-24.0	0.10551	0.04598	0.06141
-24.5	0.11872	0.05126	0.06668
-25.0	0.14798	0.06470	0.08078
-25.5	0.24064	0.11223	0.12838
-25.8	0.24022	0.11203	0.12816
-26.0	0.23991	0.11189	0.12799
-26.3	0.30516	0.15640	0.17324
-26.5	0.29456	0.15442	0.17284